LETTERS 1250 Addison Street, Suite 211B, Berkeley, CA 94702 (510)524-5405 contact@homeenergy.org www.homeenergy.org ________________ DIAGNOSING AN IAQ PROBLEM I read about the problem of a reader in the Jan/Feb ’12 Home Energy (“Diagnosing an IAQ Problem,” p. 3). I also read Tamasin Sterner’s re-ply. I would like to say that I know and have worked with Tamasin and believe she is one of the best building scientists around and I think her reply is sound and right on. Locating the source of a smell is often very diffi cult. In your situa-tion, where new insulation, drywall, and paint have been installed, it would be diffi cult to identify which is the culprit. The wall orientation is also an important factor. If one of the walls faces south, then the drying and heat and moisture movement could be to the inside of your home. Of course this is only a factor if the wall experiences a lot of sun or solar loading. This is a method I’ve used to help identify the source and products that are causing odors. It is not hi tech but it works and is cheap and effective. Cut out a small section of drywall and place in a zip lock bag. I use gallon size slider freezer bags with write-on strips. Take just the insulation from the wall cavity and place in a second zip lock bag, and fi nally take a piece of drywall and insulation and place in a third zip lock bag. Let the bags sit for a few days or weeks and open and smell each bag to see which one smells like the odor in the room. It is pos-sible that it is a combination of products interacting with each other. Either way, you should know which is causing the odor. Another benefi t of opening the wall is to identify if moisture is inside the wall cavity as Tamasin mentioned. —Larry Armanda Therma-View Infrared and Energy Consultants Williamsport, Pennsylvania Senior Executive Editor Executive Editor Editor Assistant Editor Design & Production Manager Design Associate Technical Editors Alan Meier Iain Walker Jim Gunshinan Macie Melendez Kate Henke Leanne Maxwell Henry Gifford Steve Greenberg Chris Stratton Contributing Editor Steve Mann Copyeditor Irene Elmer Writers This Issue Deborah Rider Allen, Todd Hoener, Betsy Jenkins, Tina Kaarsberg, Dan Kartzman, Steve McKenna, Ruth Ann Norton, Duncan Prahl, Paul Raymer, Rebecca Stewart, Larry Zarker Publisher Advertising & Marketing Manager Controller Office Manager Fulfillment Manager O ffice Assistant Tom White Carol A. Markell Jan Elkington Maggie Forti Alana Shindler Toni White Advertising Home Energy requires all advertisers to provide documentation to support any claims of product effi ciency and performance contained in ads. We welcome companies involved in residential conservation to join this select group. It includes manufacturers of conservation materials, tools, instrumentation, computer software, and effi cient appliances, and providers of technical services, training, and labor. For advertising rates, contact: Carol A. Markell, Home Energy , 1250 Addison Street, Suite 211B, Berkeley, CA 94702. Tel: (510)524-5405, e-mail: CAMarkell@homeenergy.org. Home Energy is published by Energy Auditor & Retrofi tter, Incorporated President, Alan Meier Executive Director, Tom White Board of Directors Karen Butterfi eld Robert Knight David Canny Joseph Kuonen Alan Meier Bill Parlapiano III Ted Pope John B. Smith Iain Walker Steve Baden Marcus Bianchi Michael Blasnik Chris Dorsi Doug Garrett Theresa Gilbride Ron Judkoff Rick Karg Courtney Moriarta John Porterfi eld Greg Thomas Linda Wigington Edward Wyatt Larry Zarker SunPower Corporation Bevilacqua-Knight, Incorporated Pacifi c Gas & Electric CLEAResult Lawrence Berkeley National Laboratory PECI Energy Solutions Johns Manville Lawrence Berkeley National Laboratory RESNET National Renewable Energy Laboratory M. Blasnik & Associates Saturn Resource Management, Inc. Building Performance & Comfort, Inc. Pacifi c Northwest National Laboratory National Renewable Energy Laboratory R. J. Karg Associates Sangfroid Associates eZing, Inc. Performance Systems Development ACI Scientifi c Certifi cation Systems Building Performance Institute THE UPSIDE OF DOWNLIGHTS I would like to offer another idea for fi xing the overheating recessed-light problem that editor Jim Gunshinan mentioned in his response to the questioner in “The Down-Low on Downlights” letter (Jan/Feb ’12, p. 4). This is how I handled the problem in my home. About fi ve years ago I purchased a home that was built in 1976. It had inadequate insulation in the attic and 11 non-IC-rated recessed lights in the ceiling. I wanted to insulate the attic to R-49, but I couldn’t safely cover the recessed lights, since they were not IC (insulation coverage) rated. I considered building a foam box over each one, but knew that this could overheat the fi xtures. I had decided to install kits to convert them to pendant lights to get the lamps outside of the fi xtures. I went to Lowe's to purchase the kits, when by a stroke of good luck, I ran into an electrician friend of mine. I told him what I was planning, and he had a better idea. He informed me that recessed lights come in two different types, new construction and remodel. He told me that I could install IC-rated remodel kits and then I would be able to insulate over them without fear of overheating. I took his advice, and even though I am not a skilled electrician by any means, I was able to change out all of the recessed fi xtures myself and I did it without going into the attic. It was pretty easy, and at the time, I was able to complete the project for under $300. Editorial Advisory Board Home Energy (ISSN 0896-9442) is a bimonthly publication of Energy Auditor and Retrofitter, Incorporated, 1250 Addison Street, Suite 211B, Berkeley, CA 94702. EA&R is a nonprofit organization dedicated to the dissemination of objective information on residential energy conservation. Yearly subscription rate: $75 for six issues. Canada and other foreign countries U.S.$90, payable by U.S. money order only. Subscribe on our Web site at www.homeenergy.org. Periodical postage paid at Berkeley, California, and additional mailing office. postmaster: Send address changes to Home Energy, 1250 Addison Street, Suite 211B, Berkeley, CA 94702. Return undeliverable Canada addresses to: Station A, PO Box 54, Windsor ON N9A 6J5, e-mail: returnsIL@imex.pb.com. Energy Auditor and Retrofitter, Incorporated, gratefully accepts contributions from institutions and firms interested in promoting energy conservation. © Copyright 2012, Energy Auditor and Retrofitter, Incorporated. Energy Auditor and Retrofitter, Incorporated, grants authorization to photocopy material from Home Energy for internal or personal use under circumstances that do not violate the fair use provisions of the copyright act. For permission to reprint, write to the above address. Printed on recycled paper www. homeenergy.org 3

LETTERS

DIAGNOSING AN IAQ PROBLEM<br /> I read about the problem of a reader in the Jan/Feb ’12 Home Energy (“Diagnosing an IAQ Problem,” p. 3). I also read Tamasin Sterner’s reply. I would like to say that I know and have worked with Tamasin and believe she is one of the best building scientists around and I think her reply is sound and right on.<br /> <br /> Locating the source of a smell is often very difficult. In your situation, where new insulation, drywall, and paint have been installed, it would be difficult to identify which is the culprit.<br /> <br /> The wall orientation is also an important factor. If one of the walls faces south, then the drying and heat and moisture movement could be to the inside of your home. Of course this is only a factor if the wall experiences a lot of sun or solar loading.<br /> <br /> This is a method I’ve used to help identify the source and products that are causing odors. It is not hi tech but it works and is cheap and effective.<br /> <br /> Cut out a small section of drywall and place in a zip lock bag. I use gallon size slider freezer bags with write-on strips. Take just the insulation from the wall cavity and place in a second zip lock bag, and finally take a piece of drywall and insulation and place in a third zip lock bag. Let the bags sit for a few days or weeks and open and smell each bag to see which one smells like the odor in the room. It is possible that it is a combination of products interacting with each other. Either way, you should know which is causing the odor.<br /> <br /> Another benefit of opening the wall is to identify if moisture is inside the wall cavity as Tamasin mentioned.<br /> —Larry Armanda<br /> Therma-View Infrared and Energy Consultants Williamsport, Pennsylvania<br /> <br /> THE UPSIDE OF DOWNLIGHTS<br /> I would like to offer another idea for fixing the overheating recessedlight problem that editor Jim Gunshinan mentioned in his response to the questioner in “The Down-Low on Downlights” letter (Jan/Feb ’12, p. 4). This is how I handled the problem in my home.<br /> <br /> About five years ago I purchased a home that was built in 1976. It had inadequate insulation in the attic and 11 non-IC-rated recessed lights in the ceiling. I wanted to insulate the attic to R-49, but I couldn’t safely cover the recessed lights, since they were not IC (insulation coverage) rated. I considered building a foam box over each one, but knew that this could overheat the fixtures.<br /> <br /> I had decided to install kits to convert them to pendant lights to get the lamps outside of the fixtures. I went to Lowe's to purchase the kits, when by a stroke of good luck, I ran into an electrician friend of mine. I told him what I was planning, and he had a better idea. He informed me that recessed lights come in two different types, new construction and remodel. He told me that I could install IC-rated remodel kits and then I would be able to insulate over them without fear of overheating. I took his advice, and even though I am not a skilled electrician by any means, I was able to change out all of the recessed fixtures myself and I did it without going into the attic. It was pretty easy, and at the time, I was able to complete the project for under $300.<br /> <br /> This is a matter of personal taste. I wanted to use Cfllamps and have never liked the flood-style CFLs, so I installed white trim packages into the recessed cans to get good reflectance and then just used regular 23W Cfltwisters. Since I have flat 8-foot ceilings, they look good, because you really don’t see the bulbs unless you are directly below the fixture looking up. And they do a pretty good job of lighting the areas they are in. Any screwin lamp could be installed safely into these fixtures. For example, if I ever wanted to install a dimmer, I could use incandescent, dimmable CFL, or LED flood lamps.<br /> <br /> After the new light fixtures were installed, I was very comfortable installing the R-49 insulation over them. I didn’t air seal the lights for two reasons. The IC-rated cans that I installed were very tight, not full of holes like many recessed cans. Also, believe it or not, my house is very tight; well below minimum ventilation level. So I didn’t want to make it any tighter. I don’t have mechanical ventilation in the house. I need to crack a window now and then as it is.<br /> —Edward Monson<br /> Benton PUD, Energy Efficiency Advisor II Kennewick, Washington<br /> <br /> Editor Jim Gunshinan replies:<br /> I didn’t like the Cflfloods that we first installed in our downlights either, even though they solved our overheating problem. And we couldn’t find a good dimming Cflflood. Our local Home Depot had a sale on Cree LED downlight kits ($39 each, still high). As you mentioned in your e-mail, these are for retrofits. After a little sweating and finagling, I replaced five of our recessed-can lights with the LED kits, and we are very happy with the dimming ability and the light quality.<br /> <br /> The contractor who did our energy retrofit installed foam board boxes over the downlights from the attic side and blew cellulose over them. In our case, most of the air leaks in our house were happening though the old, inefficient can lights, so we wanted to air seal as much as possible; plenty of fresh air is getting through in other places.<br /> <br /> MORE DOWNLIGHTS …<br /> I just read Jim Gunshinan’s response to a reader who asked a question about different lamps in recessed lights (“The Down-Low on Downlights,” Jan/Feb ’12, p. 4). I would like to add that on the inside portion of the recess housing there should be a sticker showing acceptable lamp/trim combinations, and there should also be wing nut that will allow the lamp socket to be positioned correctly for the lamp. Few people consult the information that is available to them right on the fixture. Many manufacturers also make trims that can replace the existing trim to make the fixture airtight. Homeowners can easily increase the energy efficiency of their home as well as update the look of their lighting. As always, consult the manufacturer’s instructions.<br /> —Robert De Vries<br /> Technical Services Nu-Wool Co., Incorporated Jenison, Michigan<br /> <br /> Jim Gunshinan replies:<br /> I have been inspired to replace my Cfldownlights with LED kits from Cree. I discovered the wing nut adjustment option, and a few metal screws, to adjust the can to accept the new light kit. It was easy after the first one. Now I have five LED downlights and four CFLs. The LED kits were $39, though; a bit much, but not for energy geeks like us.

Previous Page  Next Page


Publication List
 

Loading